Intel Rapid Storage Technology RAID Driver 12.8.0.1016 for Windows 7/8/8.1 Windows Server 2008/2012 x86/x64
User Drivers » RAID & HD Controller » Intel »
Date Added: August 11, 2013 / Publisher:Intel / File Size: 0.35 MB
OS: Windows 7, Windows 7 x64, Windows 8, Windows 8 x64, Windows Server 2008, Windows Server 2008 x64, Windows Server 2008 R2 x64, Windows Server 2012, Windows Server 2012 x64, Windows 8.1, Windows 8.1 x64
Release Date: August 11, 2013.
Release Date: August 8, 2013.
Resolved Issues in 12.8.0.1016 Production Version release:
- RST driver disables LPM (HIPM/DIPM) when system enters S4.
- Bad status bytes when sending ATA Smart Command Transport (SCT) commands.
- BSOD 0x7A occurred when run WinPMT Hibernation Focus.
- Zpodd: Start Stop Unit command fails when drive is asleep.
- C5 BSOD when shut down the system from start menu.
Known Issues in 12.8.0.1016 Production Version release:
- BLA cannot detect storage device with RST Driver version -CSMI.
- Option to keep data present on certain fully partitioned disks in GPT format scheme when should not be.
- WHQL: DF - Sleep With IO During (Certification) failure in RST 12.8 (NOT BLOCKING).
- UI: Format issue with Server 2012 string in System Requirements help page.
- SSHD accelerated in max mode with iSCT loaded onto system causes system to hang when trying to restart or go into S4.
- UI sporadically crashes during volume delete operations.
- UI: Help Icon present on Status page when it should not be present with only 1 SSHD (OS) attached to the system.
- BSOD "Driver Power State Failure" when accelerated HDDpw volume is locked upon wake up from S4.
- Invoking "Create Additional Volume" page yields an unknown error.
- System hung on a Black screen or reboot when resuming from S1-S3 (S3 after S1).
- UI Help - Getting Started Page - Incorrect Grammar.
- UI: Day field in Verify and Repair Scheduler does not set the Next Scheduled Run correctly.
- UI: Disk Events Help Page has incorrect images.
- ATAPI Pass-through path only handles Packet Identify Device.
- Ability to change write-cache buffer flushing policy is broken after changing volume name.
- After configuring SRT and conducting Dirty Shutdowns error: Unable to find System Disk.
- BSOD 0xF4: Accelerate/Change NVM mode to Enhanced/ Changing RST Caching mode to Enhanced on disk.
- Bad Block Tests Fail With Volumes Going Degraded During the Verify and Repair Operation.
- CLI Command --accelerate --stats always returns 100% cache full.
- Constant events being sent after RRT creation.
- Deleting a non-OS matrix volume while it is migrating marks added disks as unknown.
- Failing R0 volume amidst an i/o onto it while system is in S3 causes system to hang/crash upon resume.
- Dynamic storage Accelerator: Setting system performance mode to "HighPerformance" does not cause gear to change to gear 3.
- Missing Mark Disk as Online event in Driver.
- RRT PM S4 command issued but does not recover.
- RRT failed master disk goes offline when setting disks to normal.
- RST Driver - Test hangs while running Inquiry command on ODD.
- RSTCLI allows RAID volume comprised of SSDs to be accelerated.
- SRT Driver Fails "No Spin" TIME IOCTL request on FIRST S0 following S3 with PUIS enabled.
- SRT volumes do not report disk RPM = 1, breaks Win8 Connected Standby.
- SRT: Driver fails to enumerate an accelerated disk or volume during an F6 install if a system disk is already attached to the system.
- UI Accessibility: Refresh issues when changing theme and arrow keys not functional in Help window.
- UI Unknown error enabling Volume write-back cache.
- UI allows locked spare disk to be reset to available after S4 resumption; exercising the option induces errors.
- UI erroneously exposes option to increase size of a >2TB volume if is created via the OROM.
- UI hangs and throws unknown error if we attempt to update data on an OnREQ RRT vol of SSDs.
- UI reports Unknown status and incorrect sync mode after hot-removing the recovery disk of an IRRTm while the sync is initializing.
- UI shows "Mark as normal" link while a volume is rebuilding.
- UI will sporadically fail to refresh itself to render Enable acceleration and Refresh button clickable.
- UI: "WARNING:" text missing on "Disassociate Cache and Accelerated Device" Popup Window.
- WHQL: 0xCE BSOD during DP CPU Hot Add simulation on Server 2008 R2.
- WHQL: RST not compliant with Device.DevFund.Memory.DriverFootprint requirements for x86.
- ZPODD power off timer does not reset upon receipt of CSMI I/O.
Recent Drivers
Intel RAID Controller RS3FC044/RS3GC008/RS3UC080 Firmware Update Package ph1_2013.08.16
Intel Rapid Storage Technology RAID Driver 12.8.0.1016 for Windows 7/8/8.1 Windows Server 2008/2012 x86/x64
Intel Solid-State Drive (SSD) Data Center Tool 1.1 for Windows/Linux
Intel Solid-State Drive Toolbox 3.1.6 for Windows XP/Vista/7/8
Intel SATA Solid-State Drive Firmware Update Tool 2.0.4